Six-Nines Reliability | Flash-Like Performance | Endless Evolution |
• Innovative SmartMatrix full-mesh architecture tolerates the
failure of three out of four controllers without interrupting
services .• User-mode upgrades allow users to upgrade modules without
restarting controllers .• Gateway-free active-active deployment for SAN and NAS supports smooth upgrade to geo-redundant Three-Data-Center (3DC)/Four-Data-Center (4DC) Disaster Recovery (DR) solutions. | • Innovative SmartAcceleration technology uses the dynamic adaptive
data layout algorithm to accelerate hot data, resulting in two times higher performance than the preceding generation. • The system supports high-density snapshots while meeting high
performance and reliability service requirements. • End to End (E2E) Non-Volative Memory express (NVMe) architecture
slashes latency to just 0.05 ms for a premium, all-flash experience. | • A single storage system meets the diverse needs of multiple
services — block, files, container, virtualization, and more
—yielding higher storage utilization and lower Total Cost of
Ownership (TCO). • The ransomware protection solution features Air Gap, secure
snapshots, and E2E encryption technologies to effectively defend
against ransomware attacks*. • The system supports private and hybrid clouds, as well as cloud
backup services, providing users with multiple cloudification
strategy choices. |
Model | OceanStor 6810 | OceanStor 18510 | OceanStor 18810 | |||
Hardware Specifications | ||||||
Maximum Number of Controllers | 16 | 32 | 32 | |||
Maximum Cache (Dual Controllers, Grows with the Expansion of
Controllers) | 512 GB to 16 TB | 512 GB to 32 TB | 1 TB to 32 TB | |||
Supported Storage Protocols | FC, iSCSI, NFS, CIFS, FC-NVMe, NVMe over RoCE, FTP*, HTTP*, NDMP,
S3*, SFTP* | |||||
Front-End Channel Port Types | 8/16/32 Gbps FC/FC-NVMe, 1/10/25/40/100 Gbps Ethernet, 25
Gbps/100Gbps NVMe over RoCE/NFS over RDMA | |||||
Back-End Channel Port Types | 100 Gbps RDMA/SAS 3.0 | |||||
Maximum Number of Hot-Swappable I/O Modules per Controller Enclosure | 28 | |||||
Maximum Number of Front-End Host Ports per Controller Enclosure | 80 | 96 | ||||
Maximum Number of Disks | 3200 | 6400 | 9600 | |||
Disk Types | NVMe TLC SSD, SAS TLC SSD, SAS, NL-SAS | |||||
Software Specifications | ||||||
RAID Levels | RAID 10*, 5, 6 and RAID-TP (tolerating simultaneous failure of
three disks) | |||||
Value-Added Software | SmartAcceleration, SmartVirtualization, SmartMigration, SmartThin,
SmartQoS, SmartQuota, SmartMulti-Tenant, SmartCompression,
SmartDedupe, SmartContainer*, SmartMigration for NAS,
SmartMobility, SmartMove, HyperSnap, HyperReplication, HyperClone,
HyperMetro, HyperCDP, HyperLock, HyperMetro-Inner*, HyperDetect,
HyperEncryption, HyperLink, CloudVxLAN, CloudBackup*, NFS+ | |||||
Storage Management Software | DeviceManager, UltraPath, DME IQ | |||||
Electrical Specifications | ||||||
Power Supply | 200V to 240V AC±10%, 240V DC±20% | Cabinet: 200V to 240V AC±10%, 346V to 415V AC±10%, 192V to 288V DC | ||||
Dimensions (H x W x D) | Controller enclosure: 175 mm x 447 mm x 865 mm SAS disk enclosure: 86.1 mm × 447 mm ×410 mm NVMe disk enclosure: 86.1 mm × 447 mm × 620 mm NL-SAS disk enclosure: 175 mm x 447 mm x 488 mm | Maximum cabinet dimensions: 1200 mm × 600 mm × 2000 mm Controller enclosure: 175 mm x 447 mm x 865 mm SAS disk enclosure: 86.1 mm × 447 mm × 410 mm NVMe disk enclosure: 86.1 mm × 447 mm × 620 mm NL-SAS disk enclosure: 175 mm x 447 mm x 488 mm | ||||
Weight (Incl. Disk Units) | Controller enclosure ≤ 88.2 kg SAS disk enclosure ≤ 19.65 kg NL-SAS
disk enclosure ≤ 43.9 kg Smart NVMe disk enclosure ≤ 33.95 kg | Controller enclosure ≤ 88.2 kg SAS disk enclosure ≤ 19.65 kg NL-SAS disk enclosure ≤ 43.9 kg Smart NVMe disk enclosure ≤ 33.95 kg System cabinet ≤ 700 kg Disk cabinet ≤ 600 kg | ||||
Operating Temperature | -60 m to +1800 m altitude: 5°C to 35°C (cabinet) or 40°C
(enclosure) 1800 m to 3000 m altitude: The maximum temperature threshold decreases by 1°C for every altitude increase of 220 m | |||||
Operating Humidity | 10% to 90% RH | |||||


















|